OEM Manufacturer Three Channel Ecg Paper 80*20m - 24 Hours Of ECG Detection 3-6-12-lead Multi-parameter Bed-side Patient Monitor For ICU CCU – Grand
OEM Manufacturer Three Channel Ecg Paper 80*20m - 24 Hours Of ECG Detection 3-6-12-lead Multi-parameter Bed-side Patient Monitor For ICU CCU – Grand Detail:
Product Description
PM-7000D
Multi-parameter Bed-side Patient Monitor
Overview
Application: Adult/Pediatric/Neonatal/Medicine/Surgery/Operating Room/ICU/CCU
Features: Light & handy
Measurement: ECG/ SpO2/NIBP/HR&PR/Temp/Resp
Network: Wire/wireless network & online update
Triplex alarms: Light/Message/Sound (support real voice)
(High/medium/low levels adjustable)
Electrode Disconnection Alarm (Diagram)
Linux Operating System
Easy operation/stable performance
Electrotome/defibrillation tolerance
Restore within 5 seconds after defibrillation
Power Supply:AC & DC
Data Storage
Trend diagram/table: 1000h
NIBP review: 2000 events
Wave review: 48h (optional)
Alarm review: 200 alarm events
Support drug concentration titration analysis
Physical Specification
Dimension & weight
Equipment: 308mm×141mm×273mm; 4.5 kg
Package: 420mm×290mm×370mm; 6.5 kg
Monitor: 12.1” real color LED screen
Battery:
2200mAh
3h operating after full charge
30min operating after low battery alarm
Electrical Power
AC: 100 ~ 240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Environmental Conditions
Temperature:
Working 5 ~ 40°C
Storage -20 ~ 55°C
Humidity:
Working 20% ~ 85%
Storage 10% ~ 95%
Pressure:
Working 70.0 kPa ~ 106.0kPa
Storage 50.0 kPa ~ 106.0kPa
Technique Specification
ECG
5 Leads: RA, LA, LL, RL, V
Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V
Gain: ×0.25, ×0.5, ×1.0, ×2.0, (error≤5%)
Sweep speed: 12.5mm/s,25mm/s,
50mm/s (error≤±10%)
Bandwidth: Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
Sensitivity: >200 μV P-P
CMRR: Diagnostic: >90dB
Monitor: ≥100dB
Surgery: ≥100dB
Polarization Voltage: ±300mV
Input Impedance: >5 M ohm
Calibration Voltage: 1mV±5%
ST Segment Range:
-2.0mV ~ +2.0mV (unspecific)
-0.8mV~ +0.8mV (accuracy 0.02mV)
Double Insulation Protection
(4000VAC/50Hz)
Defibrillation tolerance
High frequency electrotome tolerance
AC and Drift tolerance
Support heart Pace-making Analysis
13 Arrhythmia Analysis:
Asystole, V-Fibrillation/Tachycardia,
Single/Paired/Multiform PVC, Bigeminy,
Trigeminy, Polycardia, P-0N-T,
Bradycardia, Leaky-wave, Pacemaker
not captured, Pacemaker failure
SpO2 (Fields)
Measurement range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100% ±3 DIGIT
0% ~ 69% (unspecified)
Pulse rate:
Measure/alarm range 20 ~ 300bpm
Resolution 1bpm
Accuracy 20 ~ 300bpm (±3bpm)
NIBP
Method: Oscillometry
Measure mode: Manual, Auto, STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40 ~ 240bpm
Measure & alarm range:
Adult mode
SYS 40 ~ 270mmHg
DIA 10 ~ 215mmHg
MEAN 20 ~ 235mmHg
Pediatric mode
SYS 40 ~ 200mmHg
DIA 10 ~ 150mmHg
MEAN 20 ~ 165mmHg
Product detail pictures:
Related Product Guide:
We always continually provide you with the most conscientious customer service, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for OEM Manufacturer Three Channel Ecg Paper 80*20m - 24 Hours Of ECG Detection 3-6-12-lead Multi-parameter Bed-side Patient Monitor For ICU CCU – Grand , The product will supply to all over the world, such as: Angola, Turkmenistan, Jakarta, If any item be of interest to you, please let us know. We will try our best to satisfy your requirements with high quality products, the best prices and prompt delivery. Please feel free to contact us at any time. We will reply you when we receive your inquiries. Please note that samples are available before we start our business.